SC-Port Pinouts SC-Port to SC-Port Cable Wiring
ST-Port Pinouts ST-Port to ST-Port Cable Wiring
This is Class 1 Laser/LED product. Do not stare into the Laser
Beam.
Redundant Power Inputs
Both power inputs can be connected simultaneously to live DC power
sources. If one power source fails, the other live source acts as a
backup, and automatically supplies all of MOXA Industrial Media
Converter’s power needs.
Alarm Contact
MOXA Industrial Media Converter has one Alarm Contact located on
the top panel. For detailed instructions on how to connect the Alarm
Contact power wires to the two middle contacts of the 6-contact
terminal block connector, see the Wiring the Alarm Contact section
above. A typical scenario would be to connect the Fault circuit to a
warning light located in the control room. The light can be set up to
switch on when a fault is detected.
The Alarm Contact has two terminals that form a Fault circuit for
connecting to an alarm system. The two wires attached to the Fault
contacts form an open circuit when (1) IMC has lost power from one of
the DC power inputs, or (2) one of the ports for which the corresponding
PORT ALARM Dip Switch is set to ON is not properly connected.
If neither of these two conditions occurs, the Fault circuit will be closed.